INSTALLATION
Your JUN-AIR compressor unit is easy to operate. Observe
the instructions and you will get many years service from
your compressor.
Visually inspect unit for shipping damage, contact your
supplier immediately if you think the unit may have been
damaged.
Mount inlet filter
Check that the performance of the compressor matches
the actual air consumption
Check that the rating label of the compressor corresponds
with the electrical voltage offered and check that fusing is
adequate.
Start the compressor using the 0/1 switch on the pressure
switch
Placing
Place the compressor in a dustfree, dry and cool, yet
frostfree room.
Sufficient cooling from the surroundings is important.
Ambient temperature: 0°C - 40°C, 32°F - 104°F
Relative humidity: Max 90%
OPERATION
If the compressor has been stored at an extremely low
temperature, allow it to heat to room temperature before
switching it on.
Do not use motor for compression of liquids and dangerous
gasses, such as petrol vapour and solvents.
The cut-in and cut-out pressure is preset from the factory.
All compressors are designed for 100% duty but 50%
operation is recommended to prolong the lifetime.
Do not lubricate the oil-less motor with oil, as it will destroy
important components.
TECHNICAL SPECIFICATIONS
Model
Voltage Volt 220-240 220-240 220-240
Frequency Hz 50 50 50
Power kW 0,25 0,25 0,50
Displacement l/min. 90 90 180
FAD @ 7barg
FAD @ 5barg
l/min.
28
40
28
40
56
80
Max.
pressure
barg 7 7 7
Max. current Amps 2,4 2,4 4,8
Weight Kg 16 24 33
Dimensions mm 351x327x286 622x336x536 622x336x536
Noise level
@ 1m
dB(a) 70 70 72
Tank size l 4 25 25
Pumping
time
min.
sec.
0
32
3
32
1
42
SAFETY
Important - read this first!
Please read the following information and operating
instructions included with this product before use. This
information is for your safety and it is important that you
follow these instructions. It will also help prevent damage to
the product. Failure to operate the unit in accordance with
the instructions or using JUN-AIR unauthorized spare parts
can cause damage to the unit and could cause serious
injury.
IMPORTANT: General directions for
installation
If the compressor is not fitted with a supply plug a
circuit breaker must be incorporated in the fixed wiring.
If this unit is supplied with a three-pin plug, connect
with a properly earthed outlet only.
CAUTION: To reduce risk of electric shock
Only authorized service agents should carry out
service. Removing parts or attempting repairs can
create an electric shock. Refer all servicing to qualified
service agents.
WARNING: To reduce risk of electrocution
Do not use this unit with electrical voltages other than
stated on the rating plate.
Always unplug this unit immediately after use and
store in a dry place.
Do not use this product in or near liquid or where it can
fall or be pulled into water or other liquids.
Do not reach for this product if it has fallen into liquid.
Unplug immediately.
This unit is not weatherproof. Never operate outdoors
in the rain or in a wet area.
DANGER: To reduce risk of explosion or
fire
During spraying with combustible liquids risk of
explosion may arise, particularly in closed rooms
Do not use this product in or near explosive
atmospheres or where aerosol products are being
used.
Do not pump any other gases other than atmospheric
air.
Do not pump combustible liquids or vapours with this
product; do not use it in or near areas with combustible
or explosive liquids or vapours.
Do not use this unit near naked flames.
CAUTION: To prevent injury
Compressed air can be dangerous; do not direct
airflow at a persons head or body.
Always keep the compressor out of reach of children.
Never operate this product if it has a damaged power
lead or plug, if it has been dropped or damaged, or if
it has fallen into water. Return the product to a service
centre for examination and repair.
Keep the electrical cable away from hot surfaces.
Ensure all openings are kept free of restriction and
never place the motor on a soft surface where the
openings may be blocked. Keep all openings free from
dust, dirt and other particles.
Never leave this product unattended when plugged in.
Never insert fingers or any other objects into fans.
This unit is thermally protected and can automatically
restart when the overload resets.
Wear safety glasses, when servicing this product.
Use only in well ventilated areas.
This product may only be connected to units or tools
with a max. pressure higher or equal to that of the
compressor.
The surface of the compressor can get hot. Do not
touch compressor motor during operation.
Failure to observe the above safety precautions could
result in severe bodily injury, including death in extreme
cases.
IMPORTANT: General directions for use
Protect compressor against rain, moisture, frost and
dust.
The compressor is constructed and approved
for a max. pressure as stated under Technical
Specifications.
Do not operate compressor at ambient temperatures
exceeding 40°C/104°F or falling below 0°C/32°F.
If the supply lead on the compressor is defective,
an authorized JUN-AIR distributor or other qualified
personnel must carry out the repair.
WARRANTY
Provided that the instructions for operation, maintenance
and service have been carried out, your JUN-AIR
compressor is guaranteed against faulty material or
workmanship for 2 years or 5000 hours what ever comes
first.
The air receiver is guaranteed for 2 years.
The guarantee does not cover damage caused by violence,
misuse, incorrect repairs or use of unoriginal spare parts.
Costs of transportation of parts/equipment are not covered
by the guarantee.
JUN-AIR’s Conditions for Sale and Delivery will generally
apply.
JUN-AIR International A/S reserves the right to change
technical specifications/constructions.
PREVENTIVE MAINTENANCE
Activity Weekly Monthly
Once a year or
every 2000 h
a Drain condensate
b Check filter
c Check for leaks
d Clean the unit
e Check safety valve
f Check intake filter
g Check non-return valve
a) Drain condensate
Filter regulator
Unscrew the bowl of regulator to empty filter.
Receiver
Turn the outlet valve counterclock wise one quater of a
turn. Sound will occur.
b) Check filter at filter regulator
Check and change the filter element.
c) Check for leaks
Check motor, hoses and equipment for leaks. Check the
pumping time.
d) Clean the unit
Clean the unit when needed with a soft, damp cloth. If
necessary, use detergent to remove adhesions. Dust and
dirt prevent cooling.
e) Check safety valve
Check the safety valve with pressure in the receiver. The
safety valve is operated by pulling the ring. WARNING loud
noise.
f) Check intake filter
Check the intake filter and change filter element if
necessary.
g) Check non-return valves
Turn off the compressor on the main switch and pull out the
plug.
Empty the receiver for compressed air by operating the
safety valve. WARNING loud noise. When the receiver is
empty, the reading of the pressure gauge is 0 bar.
Dismount the non-return valve from the receiver.
Disassemble the non-return valve and remove the O-ring
from the piston.
Clean the non-return valve.
Mount a new O-ring and re-assemble the non-return valve.
Re-install the non-return valve.
Service kit 5471004
Contains:
1 pcs 4081603 5µ filter element
2 pcs B344A Intake filter element
3 pcs 6243000 O-ring brown f/non-return valve
Spare parts
4071052 Filter Regulator
5130000 Pressure Gauge
B300A Inlet Filter
2893001 Motor Compressor 82R642
6189510-v.02-01.2010 GAST JUN-AIR International A/S, Sundsholmen 3-5, 9400 Nørresundby, Denmark, +45 96 32 36 00 www.jun-air.dk Page 1
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1

INSTALLATIONYour JUN-AIR compressor unit is easy to operate. Observe the instructions and you will get many years service from your compressor.Visuall

Page 2

MODE D’EMPLOI GÉNÉRALImportant!Veuillez lire les instructions ci-jointes avant de mettre votre compresseur en marche. Ces instructions sont prévues p

Page 3

SIKKERHEDVigtigt - læses før ibrugtagning!Læs og forstå følgende information før brug. Denne information er lavet for Deres sikkerhed og for at forhin

Page 4 - JUN-AIR INTERNATIONAL A/S

GB The manufacturer JUN-AIR International A/S declares that the compressor is in conformity with:87/404/EEC - 90/488/EEC - 93/68/EEC Council Directiv

Commentaires sur ces manuels

Pas de commentaire